ArchiveIndustry NewsPlumbing

NSF International Publishes New Criteria for Drinking Water Treatment Standard

The joint committee of experts that maintains an NSF International drinking water treatment standard has recently updated it to allow a more efficient method of treating microorganisms in drinking water. The revision to NSF/ANSI 55: Ultraviolet Microbiological Water Treatment Systems establishes new criteria for use of UV-LED technology for microbial reduction and provides a new test method to certify manufacturer claims.

Treatment systems covered by the standard use ultraviolet light to inactivate or kill bacteria, viruses and cysts in microbiologically unsafe water (Class A systems) or to reduce the amount of non-disease-causing bacteria in disinfected drinking water (Class B systems).

“This is a significant update to the drinking water treatment standard. While non-disinfecting LEDs are found in everyday applications, such as lighting fixtures and consumer electronics, this use of ultraviolet LED technology is very different. Lab testing shows that ultraviolet LED technology is effective at reducing bacteria and other types of microorganisms in drinking water,” said Jessica Evans, director of standards development at NSF International. NSF is accredited by the American National Standards Institute to develop standards using its consensus-based process with a balanced group of stakeholders.

Originally developed in 1991, NSF/ANSI 55’s scope was limited to low-pressure ultraviolet radiation systems using low-pressure mercury bulbs, which was the only technology available in the marketplace at the time.

In 2014, the Drinking Water Treatment Units Joint Committee responsible for the NSF/ANSI standard began developing a protocol to address newer alternate UV technologies.

After considering several options, a task group recommended the approach of running a direct log-reduction test with an organism that would represent an entire class of organisms.

The task group concluded that the virus Q-beta is an acceptable surrogate to Rotavirus and the test method performs appropriately. This holds true at both ends of the UV wavelength range examined (254 nm to 285 nm). Testing with Q-beta directly is also a simpler, more consistent and less expensive protocol than having to conduct the collimated beam study required in the original protocol.

The existing protocol for systems will remain in NSF/ANSI 55 for at least five years. Manufacturers will have the option to evaluate their product to the new test method or the older test method defined within the standard. For devices with wavelengths other than 254 nm, the new method using Q-beta would be required and would have the following criteria:

  • 4-log reduction of Q-beta at the alarm set point for Class A devices
  • 5-log reduction of Q-beta for Class B with UV source irradiance at 70% normal output or 2.14-log reduction with UV source irradiance at 100% normal output

Related Articles

Back to top button

Adblock Detected

Please consider supporting us by disabling your ad blocker